4.9 Operation and configuration of the control unit
ATD4xxW Door Controller for Industrial Applications
174
System Manual, 01/2017, A5E38080677-AB
4.9.5.3
Parameter assignment
The tables below show all the parameters that are available via the PKW interface. The
parameters are generally subdivided into:
●
Driving parameters
●
Fieldbus parameters
●
Other parameters
●
Calibration and function parameters
●
Obstruction and reversing parameters
●
FBLOCK parameters
●
Basic parameters
Note
Write-protected parameters (read only) are indicated in the documentation by an "r" before
the parameter number.
Read / write parameters can be changed, and are indicated by a "p" before the parameter
number.
Driving parameters
Note
For safety reasons, changes to the driving parameters are only accepted when the controller
is at a complete stop.
Note
Write protection
When write protection is activated (see Table 4-33 Other parameters (Page 176)), the drive
curve parameters can only be changed via the SIDOOR user commissioning software and
the PKW interface. A write-protected parameter can only be configured via the PKW
interface, and is automatically reset by an initial learn run (learn run when line voltage
applied).
Table 4- 32 Driving parameters
Parameter ID
Unit
Parameter name
Description
Distances
p3660
mm
Slow end distance open
Slow end distance in the open position
p3661
mm
Slow start distance open
Slow start distance in the closed position
p3662
mm
Slow start distance close
Slow start distance in the open position
p3663
mm
Slow end distance close
Slow end distance in the closed position