Controllers
4.9 Operation and configuration of the control unit
ATD4xxW Door Controller for Industrial Applications
182
System Manual, 01/2017, A5E38080677-AB
The parameters in the table below refer to the closing direction only.
Table 4- 37 Obstruction and reversing parameters (in the closing direction)
Parameter ID
Adjustment range
Factory set-
ting
Unit
Description
Timing
p3852
1)
0 … 60000
1000
ms
ON-delay time for obstruction detection
p3853
1)
0 … 60000
300
ms
Minimum detection time for stop obstruction
p3854
1)
0 … 60000
100
ms
Minimum detection time for force obstruction
Ranges
p3855
1)
0 … 60000
20
mm
Distance for slow obstruction approach before and
after the obstruction
p3856
1)
0 … 60000
10
mm
Range of suppression of obstruction detection
before the closed end stop
p3857
1)
0 … 60000
10
mm
Range of suppression of obstruction detection
after the open end stop
p3858
1)
0 … 60000
20
mm
Range of suppression of force obstruction detec-
tion before the creep distance
p3859
1)
0 … 60000
50
mm
Range of suppression of force obstruction detec-
tion after the last obstruction
Retries
p3860
0 to 0xFFFF
0
≙
no retry,
0xFFFF ≙ unl
imited
retries
0
—
Number of retries to overcome the obstruction
p3861
0 … 60000
2000
ms
Wait time before each retry
p3862
0 ≙ deenergize
1 ≙ stop
0
—
Drive control during the wait time (before retries)
p3863
0 ≙ deenergize
1 ≙
stop
2 ≙ open
3 ≙ close
0
—
Drive control after all retries have been executed
(if reversing is not configured)
Reversing
p3864
0 to 0xFFFF
0 ≙ no reve
rsing
0xFFFF ≙ unl
imited
reversing
2
1 (V1.03 and
higher)
—
Number of reverses
p3865
0 … 60000
2000
ms
Wait time before each reverse
p3866
0 … 60000
0 ≙ full reve
rse
200
mm
Reversing distance