ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
217
Power supply
6
6.1
SIDOOR NT40
6.1.1
Description
Intended use
The device has been designed for operation exclusively in an industrial environment, and
may only be operated in conjunction with the controllers listed in production information.
Other loads must not be connected to the output connector X2.
Note
Electromagnetic compatibility
The SIDOOR NT40 power supply meets the requirements of the EMC standard
EN 61000-6-4.
The SIDOOR NT40 power supply can cause interference if used in a residential
environment. The commissioning engineer is responsible for interference suppression.
Design
①
Power plug X1 (Schuko plug)
230 V AC (± 15 %) 50 / 60 Hz
②
Output X2 (output to controller)
36 V DC (± 3 %) 2.5 A (15 A for < 2 s)
③
LED L1
Figure 6-1
SIDOOR NT40
Summary of Contents for SIDOOR ATD401W
Page 1: ......