Appendices
A.1 Structure of user data/process data
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
297
A.1.2.9
TZW3, TZW4, TZW5 - Technology status words 3, 4, 5
The values monitored in the technology status words TZW3, TZW4 and TZW5 can be set via
the parameters p4700, p4701 and p4702.
Table A- 34 Value setting for TZW3, TZW4, TZW4
Parameter Value range Default
value
Description
p4700
0 … 9
0
Value selection for TZW3 (see following tables)
p4701
0 … 9
1
Value selection for TZW4 (see following tables)
p4702
0 … 9
2
Value selection for TZW5 (see following tables)
The default values of the parameters p4700, p4701, p4702 correspond to the settings for
TZW3, TZW4, TZW5 in FW versions < V1.09.
Table A- 35 Value selection for TZW3, TZW4, TZW4
Value Description
Format
0
D-IN
For data structure, see table A-35
1
D-OUT
For data structure, see table A-37
2
Button
For data structure, see table A-39
3
Door position in mm
16-bit unsigned integer
4
Door setpoint speed in mm/s
16-bit unsigned integer
5
Door actual speed in mm/s
16-bit unsigned integer
6
Motor current in mA
16-bit signed integer
7
Motor current limitation in mA
16-bit signed integer
8
Voltage of the motor output stage in V
16-bit unsigned integer
9
Remaining power capacity of the braking resistor in J 16-bit signed integer
Table A- 36 TZW data structure for value "D-IN"
TZW3, TZW4, TZW5
15 - 5
4
3
2
1
0
Reserved
D-IN
Table A- 37 Bits "D-IN"
Group
Bit
Meaning
Comment
D-IN
0
Input 0
X6, INPUT 1
1
Input 1
X6, INPUT 2
2
Input 2
X6, INPUT 3
3
Input 3
X6, INPUT 4
4
Input 4
X5, INPUT 0
5 - 15
Reserved