A.2.2
SIDOOR M3 L / R
Table A- 42 Parameters and adjustment range SIDOOR M3 L / R apply for the SIDOOR ATD4xxW controller
Parameter
Parameter ID
Unit
Profile 1*
Adjustment range
ATD4xxW
Slow end distance open
p3660
mm
30
0 … 100
Slow start distance open
p3661
mm
30
0 … 100
Slow start distance close
p3662
mm
20
0 … 100
Slow end distance close
p3663
mm
40
0 … 100
Maximum speed open
p3664
mm/s
650
100 … 650
30 … 650 (as of
V1.03)
Slow end speed open
p3665
mm/s
40
30 … 90
Slow start speed open
p3666
mm/s
60
30 … 90
Slow initial speed open
p3667
mm/s
90
30 … 90
Maximum speed close
p3668
mm/s
281
100 … 650
30 … 650 (as of
V1.03)
Slow start speed close
p3669
mm/s
60
30 … 90
Slow end speed close
p3670
mm/s
40
30 … 90
Slow initial speed close
p3671
mm/s
90
30 … 90
NDG speed (reduced)
p3672
mm/s
281
50 … 650
30 … 650 (as of
V1.03)
Acceleration ramp open
p3673
mm/s
2
1300
300 ... 1400
As of (V1.09): 250 ...
1400