Appendices
A.2 Profiles and adjustment ranges
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
301
A.2.3
SIDOOR MDG180 L / R
SIDOOR ATD4xxW
See Table A-42 Parameters and adjustment range SIDOOR M3 L / R apply for the SIDOOR
ATD4xxW controller (Page 299).
SIDOOR ATD4xxW
See Table A-42 Parameters and adjustment range SIDOOR M3 L / R apply for the SIDOOR
ATD4xxW controller (Page 299), SIDOOR ATD4xxW column.
A.2.4
SIDOOR M4 L / R
Table A- 43 Parameters and adjustment range SIDOOR M4 L / R apply for the SIDOOR ATD4xxW controller
Parameter
Parameter ID
Unit
Profile 1*
Adjustment range
ATD4xxW
Slow end distance open
p3660
mm
30
0 … 100
Slow start distance open
p3661
mm
30
0 … 100
Slow start distance close
p3662
mm
20
0 … 100
Slow end distance close
p3663
mm
40
0 … 100
Maximum speed open
p3664
mm/s
600
100 … 800
30 … 800 (as of
V1.03)
Slow end speed open
p3665
mm/s
40
30 … 90
Slow start speed open
p3666
mm/s
60
30 … 90
Slow initial speed open
p3667
mm/s
90
30 … 90
Maximum speed close
p3668
mm/s
177
100 … 800
30 … 800 (as of
V1.03)
Slow start speed close
p3669
mm/s
60
30 … 90
Slow end speed close
p3670
mm/s
40
30 … 90
Slow initial speed close
p3671
mm/s
90
30 … 90
NDG speed (reduced)
p3672
mm/s
177
50 … 800
30 … 800 (as of
V1.03)
Acceleration ramp open
p3673
mm/s
2
1300
300 ... 1400
As of (V1.09): 250 ...
1400
Deceleration ramp open
p3674
mm/s
2
600
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Summary of Contents for SIDOOR ATD401W