Parameter
Parameter ID
Unit
Profile 1*
Adjustment range
ATD4xxW
Acceleration ramp open
p3673
mm/s2
1300
300 … 1400*k1
250 … 1400*k1 (as
of V1.09)
Deceleration ramp open
p3674
mm/s2
600
300 … k2
250 … k2 (V1.09)
150 … k2 (as of
V1.10)
Reversal ramp open/close
p3675
mm/s2
1200
300 … k2
250 … k2 (V1.09)
150 … k2 (as of
V1.10)
Acceleration ramp close
p3676
mm/s2
500
300 … 1400*k1
250 … 1400*k1 (as
of V1.09)
Deceleration ramp close
p3677
mm/s2
500
300 … k2
250 … k2 (V1.09)
150 … k2 (as of
V1.10)
Reversal ramp close/open
p3678
mm/s2
850
300 … k2
250 … k2 (V1.09)
150 … k2 (as of
V1.10)
Idle torque open
p3679
A
1
0 … 2.5
Idle torque close
p3680
A
1
0 … 2.5
Peak torque close
p3681
A
3
0 … 5
Static force limit open
p3682
N
75
70 … 360/k1
Static force limit close
p3683
N
75
70 … 360/k1
Limit force end close
p3684
N
75
70 … 360/k1
Static NDG-force (reduced)
p3685
N
75
70 … 360/k1
Limit energy close
p1202
J
4
0 … 100
Limit energy open
p1203
J
4
0 … 100
Limit energy NDG
p1204
J
4
0 … 100
* Default profile (this profile is automatically loaded at the first commissioning)