Table A- 45 Parameters and adjustment range SIDOOR M5 L / R apply for the SIDOOR ATD4xxW controller
Parameter
Parameter ID
Unit
Profile 1*
Adjustment range
ATD4xxW
Slow end distance
open
p3660
mm
30
0 … 100
Slow start distance
open
p3661
mm
30
0 … 100
Slow start distance
close
p3662
mm
20
0 … 100
Slow end distance
close
p3663
mm
40
0 … 100
Maximum speed open p3664
mm/s
200
100 … 500
30 … 500 (as of
V1.03)
Slow end speed open p3665
mm/s
40
30 … 90
Slow start speed open p3666
mm/s
60
30 … 90
Slow initial speed open p3667
mm/s
90
30 … 90
Maximum speed close p3668
mm/s
162
100 … 500
30 … 500 (as of
V1.03)
Slow start speed close p3669
mm/s
60
30 … 90
Slow end speed close p3670
mm/s
40
30 … 90
Slow initial speed
close
p3671
mm/s
90
30 … 90
NDG speed (reduced) p3672
mm/s
162
50 … 500
30 … 500 (as of
V1.03)
Acceleration ramp
open
p3673
mm/s
2
450
300 … 650
250 … 650 (as of
V1.09)
Deceleration ramp
open
p3674
mm/s
2
300
300 … 650
250 … 650 (V1.09)
150 … 650 (as of
V1.10)
Reversal ramp
open/close
p3675
mm/s
2
500
300 … 650
250 … 650 (V1.09)
150 … 650 (as of
V1.10)
Acceleration ramp
close
p3676
mm/s
2
400
300 … 650
250 … 650 (as of
V1.09)