Diagnostic and maintenance
10.2 Fault management
ATD4xxW Door Controller for Industrial Applications
274
System Manual, 01/2017, A5E38080677-AB
Display
Meaning
Alarm
4
Automatic extension of the hold-open time (motor protection)
5
New motor type detected - learn run is required
P
Parameter error (error during learn run)
y
Master timeout
_
Controller has no parameters and is waiting for learn run
Reserve
b
–
h
–
1)
See section SIDOOR functions (Page 26)
10.2
Fault management
Faults
Faults are all arising system faults that need acknowledgement.
You will find a list of faults in the Section Operating state display (Page 273).
SIDOOR ATD410W/ATD420W/ATD430W
The system responds to faults according to the sequential control (see Figure 4-4 Sequential
control state graph (Page 149)). After acknowledgement, the controller automatically triggers
a reset after a protection time of 5 s.
Fault acknowledgment
Fault acknowledgement can take place in relation to one of the following three possibilities:
●
Corresponding terminal input prompt
●
FBLOCK "fault acknowledgement" *
●
Corresponding acknowledgment bit (bit 7) in STW1 (see Section TSW1 - technology
control word 1 (Page 287)) *
* SIDOOR ATD410W/ATD420W/ATD430W
Summary of Contents for SIDOOR ATD401W
Page 1: ......