ATE500E
System Manual, 09/2017, A5E33917696-AD
137
Connection and commissioning
9
Requirements
WARNING
Dangerous electrical voltage!
When electrical devices are operated, parts of these devices will necessarily carry
dangerous voltages. Failure to observe the operating instructions can lead to serious
injuries or material damage.
Observe the operating instructions.
Note
The motor temperature must not be below 0°C during the learn run, as otherwise the weight
of the door will be incorrectly determined, and the closing and nudge speeds may lie in
impermissible ranges.
WARNING
Risk of injury during commissioning
•
The door movements cannot always be externally controlled while the controller is being
commissioned (in particular during the automatic determination of parameters). The light
barrier is not active during the learn run.
•
Increased forces, speeds and energies arise in the closing and opening directions
during the learn run.
Therefore, ensure that the door is secured with physical barriers prior to a learn run and
during commissioning.
WARNING
Risk of injury during commissioning
Prior to the learn run, the "closed" and "open" positions are unknown. For this reason, the
direction of movement of the door resulting from pressing the OPEN (S402) or CLOSE
(S403) service buttons is dependent on the way that the door and motor have been
installed.
Increased forces arise in the opening and closing directions when positioning the door
using the OPEN (S402) and CLOSE (S403) service buttons, and before a learn run the 7-
segment display (H401) shows the status code "_" or "P". You must therefore ensure that
the door is safely cordoned off.