Controller
6.4 Operation and parameter assignment
ATE500E
46
System Manual, 09/2017, A5E33917696-AD
Note
Operation with the SIDOOR SERVICE TOOL or the SIDOOR USER SOFTWARE
The doors can also be controlled with the SIDOOR SERVICE TOOL or the SIDOOR USER
SOFTWARE. In this case, the external input signals are disabled in some menus.
You can find additional information in section SIDOOR SERVICE TOOL (Page 143) and in
the SIDOOR SOFTWARE KIT Operating Instructions
http://support.automation.siemens.com/WW/view/en/92711247
6.4.2.2
Minimal editor
Using the minimal editor
The SIDOOR ATE500E controller has a minimal editor.
The Minimal editor is a utility for changing parameters at a controller when the SIDOOR
SERVICE TOOL or the SIDOOR USER SOFTWARE is not available. In this case, the learn
run button (S401) and the two service buttons (S402, S403) are assigned second functions.
The LED display (H401) is used to visualize messages.
You can use the minimal editor to perform the following settings:
●
Select a fixed profile
●
Set the closing forces (input of the counterweight)
WARNING
Risk of injury due to moving mechanical parts
Selecting a profile overwrites the input of the counterweight.
For this reason, set the value for the counterweight (parameter 'A') last.
The minimal editor can only be activated by pressing both service buttons,S401 and S402,
and simultaneously restarting the controller (disconnecting the power supply from the
network).