SIJECT OP15B Screens
SIJECT 15/16 Operation Manual June, 2003
3-38
3.2
Manual operation screen
3.2.1 Mold open/close screen
Fig 3-31
Mold open/close screen
Operating sequences
Press Mold open/close key to enter the screen. See Fig 3-31.
Four status of mold close are displayed on the screen: slow, fast,
protection with low pressure, lock mold with high pressure. Three status
of mold open are displayed on the screen: high pressure, fast and slow.
The parameters, such as position, pressure, flow and time are set on this
screen. Additionally, users can select mold close with differential valve;
set tolorence of mold open; display the position of mold and display the
actual working times.
Mold close slow (MldClo 1)
-
set position, pressure and flow
Mold close fast (MldClo 2)
-
set position, pressure and flow
Mold protection with low pressure (MldPro)
-
set position, pressure
and flow. In addition, to protect mold from particles, users can set mold
protection time here. If mold protection with low pressure cannot be
finished within the set time, the mold will retract to the end position of
mold open and send alarm.
Mold lock with high pressure (MldLck)
-
set the pressure and flow,
as well as the time for mold lock. If mold lock signal is not detected within
the set time, the machine will stop and send alarm. Here, the indicator
will show the mold lock signal. If it is backlight, then mold lock is at
position.
Mold close with differential valve (DifValve)
-
differential valve can
be selected to add mold lock force. Users can also deselecet it.
Mold open with high pressure (MldOpn 1)
-
set position, pressure and
flow.