Display   
 

12" 

15" 

17" 

19" 

15" PRO 

Type 

TFT 

Representation 

Complete Screen 

Landscape mode 

No 

Yes 

No 

No 

No 

Onscreen Display (OSD) Setup 

Yes 

 

Screen diagonals 

12,1" 

15" 

17" 

19" 

15" 

Visible area (horizontal x vertical)

in mm 

246 x 184.5 

304,1 x 228,1 

337,92 x 270,34 376,32 x 

301,06 

304.1 x 228.1 

Viewing angle (horizontal x 

vertical) 

140° x 120° 

160° x 160° 

160° x 160° 

170° x 170° 

160° x 160° 

Pixel size in mm 

0,3075 x 0,3075 0,297 x 0,297 

0,264 x 0,264 

0,294 x 0,294  0.297 x 0.297 

Optimum resolution in pixel 

800 x 600 

1024 x 768 

1280 x 1024 

1280 x 1024 

1024 x 768 

Supported resolutions (scaled) 

VGA - XGA 

VGA - SXGA 

VGA - UXGA 

VGA - UXGA  VGA - SXGA 

Refresh Rate 

60 to 75 Hz 

 

Line frequency (typical) 

37.9 kHz 

48,3 kHz 

64 kHz 

64 kHz 

48.3 kHz 

Brightness in cd/m

2

 (nits) 

> 300 

> 250 

> 300 

> 300 

> 250 

Contrast (typical) 

> 450 : 1 

> 350 : 1 

> 650 : 1 

> 650 : 1 

> 350 : 1 

Number of colors 

> 256k 

> 16 million 

> 16 million 

> 16 million 

> 16 million 

MTBF background lighting (at 20° 

ambient temperature) 

50000 h 

 

 

Certifications and standards   

 

 

 

 

 

 

12" 

15" 

17" 

19" 

15" PRO 

EMC 

 

CE EN 55011 class A 

Yes 

 

EN 61000-3-2 

Yes 

 

 

EN 61000-3-3 

Yes 

 

 

EN 61000-6-2 

Yes 

 

 

FCC Part 15 

Yes 

 

UL 

Yes 

 

cULus 508 

Yes 

Marine 

Yes 

No 

Product safety 

 

CE EN 60950-1 

Yes 

 

Aotewell Ltd 

www.aotewell.com 

Industry Automation

HongKong|UK|China

sales@aotewell.com

+86-755-8660-6182

Summary of Contents for SIMATIC 6AV7861-1AA00-0AA0

Page 1: ...cal specifications 4 SIMATIC Industrial LCD Monitors Flat Panel Operating Instructions Compact 09 2008 A5E02313712 01 This manual is valid for devices with the order numbers n 1 2 3 4 5 6 x 0 1 6AV7861 nAA00 xAA0 6AV7861 nABx0 xAA0 6AV7861 nTA00 xAA0 6AV7861 nTBx0 xAA0 Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86 755 8660 6182 ...

Page 2: ...the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentati...

Page 3: ...Rear interfaces 10 2 6 Connecting the Cables 12 2 7 Selecting the power port extended variant 14 3 Commissioning 15 3 1 Overview 15 3 2 Switching on the device 16 3 3 Screen Configuration 16 3 4 Installing UPDD 17 3 4 1 Prerequisites 17 3 4 2 Procedure 17 3 4 3 Touch screen calibration 19 3 5 Installing applications and drivers 20 4 Technical specifications 21 Index 25 Aotewell Ltd www aotewell co...

Page 4: ...Table of contents Flat Panel 4 Operating Instructions Compact 09 2008 A5E02313712 01 Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86 755 8660 6182 ...

Page 5: ...r unit and in the CD menu only becomes available after the device is commissioned This is why the first steps for commissioning the device are described in this manual You are also supported by screen dialogs during commissioning NOTICE Carry out the tasks in the sequence described Please follow all safety instructions Read the documentation thoroughly once you have completed the commissioning Ple...

Page 6: ...Introduction Flat Panel 6 Operating Instructions Compact 09 2008 A5E02313712 01 Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86 755 8660 6182 ...

Page 7: ...y the programming configuration and wiring of the inserted I O modules have to be executed in accordance with the safety performance SIL PL or Cat identified by the necessary risk analysis The intended use of the device has to be ensured The proper use of the device has to be verified with a function test on the system This test can detect programming configuration and wiring errors The test resul...

Page 8: ... the device 4 Keep the packaging material in case you have to transport the unit again NOTICE The packaging protects the device during transport and storage Therefore never dispose of the original packaging material 5 Please keep the enclosed documentation in a safe place You will need the documentation when you start up the device for the first time 6 Check the package contents for completeness a...

Page 9: ...e 1 8 m 1 USB cable 1 8 m 1 only with Touch devices Installation guidelines 1 Template for mounting cut out 1 Operating Instructions compact 1 German 1 English Scope of delivery for Flat Panel PRO Designation Quantity Flat Panel PRO 1 CD Documentation Drivers 1 Basic adapter for fixing to a supporting arm 1 Power cable 230 V 1 Installation guidelines 1 Operating Instructions compact 1 German 1 Eng...

Page 10: ...er number 2 5 Rear interfaces Interfaces 1 Position Name Description 1 DVI Digital DVI connection 2 VGA Analog VGA connection 3 USB with Touch screen option USB connection for Flat Panels with Touch screens 4 24 V DC the 230 V AC version is closed by a cover plate 24 V DC power supply 5 230 V AC the 24 V DC option is closed by a cover plate 230 V AC power supply IEC power connector for the AC powe...

Page 11: ...supply 7 100 240 V AC 230 V AC power supply Figure 2 3 Arrangement of the interfaces extended version Interfaces Flat Panel PRO version Position Name Description 1 DVI D Digital DVI connection 2 VGA Analog VGA connection 3 USB link 5 m USB computer interface RJ45 type Is connected to the USB transmitter module when the distance exceeds 5 m 4 USB out Interfaces from the USB hub for external devices...

Page 12: ...cted by cable for data transmission Further information is available in the Description chapter of the operating instructions under the section Accessories Procedure when the distance is 5 m Connect the DVI or VGA cable to the Flat Panel and the computer unit Note Use a USB cable for the Touch Screen versions Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86...

Page 13: ...ule 6 Short connecting cable 1 Plug the female connector of the long USB connecting cable 1 into the port 2 USB link on the control unit 3 2 Plug the USB connecting cable 1 into the port 4 on the USB transmitter module 5 The control unit is connected to the USB transmitter module 3 Use the second short USB connecting cable 6 to connect the USB transmitter module to the computer unit 4 Connect the ...

Page 14: ... 01 2 7 Selecting the power port extended variant Procedure Figure 2 6 Selecting the power port 1 Loosen the screw 1 2 Slide the interlock 2 open to permit access to the required 24 V DC or 230 V AC power port 3 Tighten the screw 1 again Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86 755 8660 6182 ...

Page 15: ...ter of the operating instructions Please follow all guidelines CAUTION Condensation When transporting the device at low temperatures ensure that no moisture gets on or into the device This also applies if the device is subjected to extreme changes in temperature Wait 12 hours before switching the device on Allow the device to slowly adjust to room temperature before commissioning the device Do not...

Page 16: ...h a grounded protective conductor The device starts up 4 Switch on the computer unit 3 3 Screen Configuration Configuring the Monitor You can set the screen resolution and other parameters of the monitor using the Control Panel of the computer unit Call Start menu Start command Settings Control panel Display NOTICE A limited set of screen resolutions are available for the monitor Set the screen re...

Page 17: ...PDD software must not have been installed 3 4 2 Procedure 1 If a previous version of the UPDD software is installed please uninstall it Subsequently restart the computer Note Use the application from the Documentation Drivers CD supplied or from the Internet You can find the application under 2 Start the software by double clicking on Setup The UPDD Install dialog box is displayed This informs you...

Page 18: ...op The application emulates the right mouse button Figure 3 3 Mouse The end of the installation is displayed Figure 3 4 Installation completed 4 Confirm with Close If you call Start Programs UPDD following the installation the following functions are available Event Selector Test Settings and Calibrate Figure 3 5 Start menu Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales ...

Page 19: ...librate 4 The calibration mask is output on the selected display 6 Touch the blue arrow The input is confirmed by a tick and the next arrow is displayed 7 Confirm all input prompts arrows or crosses in the center until the complete screen has been calibrated Note If the touch screen does not react as expected when touched repeat the calibration Only an active screen can be calibrated An active scr...

Page 20: ...s available in the Operation and Configuration chapter of the operating instructions under the section OSD Menu NOTICE After commissioning your device find out more about the particulars about approvals for Microsoft Windows operating systems in the Commissioning section of the Operation and Configuration chapter Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell co...

Page 21: ...8 1 450 1 450 1 450 1 Height 290 1 290 1 380 1 380 1 Depth 51 55 57 57 Weight in kg 5 0 6 4 9 6 10 2 7 kg Installation Front installation Rack installation or front installation On the support arm Stand Special features Anti reflex and hardened mineral glass screen Dimmable backlighting The PC can be up to 30 m away from the Flat Panel option Operated as touch screen analog resistive optional resi...

Page 22: ...on in pixel 800 x 600 1024 x 768 1280 x 1024 1280 x 1024 1024 x 768 Supported resolutions scaled VGA XGA VGA SXGA VGA UXGA VGA UXGA VGA SXGA Refresh Rate 60 to 75 Hz Line frequency typical 37 9 kHz 48 3 kHz 64 kHz 64 kHz 48 3 kHz Brightness in cd m2 nits 300 250 300 300 250 Contrast typical 450 1 350 1 650 1 650 1 350 1 Number of colors 256k 16 million 16 million 16 million 16 million MTBF backgro...

Page 23: ... to 90 at max 40 C Transport and storage packed Vibration load 5 to 9 Hz 3 5 mm 9 to 500 Hz 1 g 20 Sweeps Shock load 250 m s2 6 mm 1000 shocks Ambient temperature 20 C to 60 C Relative humidity limit values 5 to 90 at max 40 C Temperature change Maximum 10 K h Condensation Not allowed Air inlet No corrosive gases Interfaces 12 15 17 19 15 PRO Video port VGA Yes DVI D Yes Interface for touch screen...

Page 24: ...nity to surges Surge EN 61000 4 5 On 24 V DC 0 5 kV symmetric asymmetric 1 kV symmetric 2 kV asymmetric Immunity to discharge of static electricity ESD EN 61000 4 2 8 kV with air discharge 4 kV on contact direct indirect Interference criterion B Interference immunity against radiated radio frequency electromagnetic fields EN 61000 4 3 80 1000 MHz 10 V m Modulation 80 AM with 1 kHz interference cri...

Page 25: ... 13 M Monitor Setting 16 N Note 7 Safety information 7 P Package contents 8 Checking 8 Packaging 8 Checking 8 Removing 8 R radiation High frequency radiation 8 Radiation 8 S Safety information 7 Setting 16 Display 16 Monitor 16 T Technical specifications Ambient conditions 23 Certifications and standards 22 Degree of protection 21 Display 22 General features 21 Interfaces 23 Supply voltage 21 Aote...

Page 26: ...x SIMATIC Industrial LCD Monitors Flat Panel 26 Operating Instructions Compact 09 2008 A5E02313712 01 Aotewell Ltd www aotewell com Industry Automation HongKong UK China sales aotewell com 86 755 8660 6182 ...

Reviews: