An FM (function module) is a module that relieves the CPU of the S7-300
and S7-400 programmable controllers of time-critical or memory-intensive
process signal handling tasks. FMs generally use the internal bus for
high-speed data exchange with the CPU. Examples of FM applications
include counting, positioning, closed-loop control.
Grounding to ensure the intended purpose of the electrical devices.
Functional grounding has the effect of short-circuiting interference voltages
that would otherwise have unacceptable effects on the devices.
Conductive ground whose electrical potential at every point can be taken as
zero.
In the area of grounding electrodes, ground can have a potential different to
zero. This is frequently referred to as “reference ground”.
To connect an electrically conductive part with the grounding electrode (one
or more conductive parts that have very good contact to ground) via a
grounding point.
H
A hardware interrupt is triggered by interrupt-triggering modules as the result
of certain events in the process. The hardware interrupt is signaled to the C7
CPU. Depending on the priority of the interrupt, the corresponding
organization block is then executed.
I
The STEP 7 info functions allow you to display status information on the
programming device via the connected C7 during the different phases of
startup and during operation of a programmable controller.
–>
MPI
The –> operating system of the C7 CPU recognizes 10 different priority
classes that control execution of the user program. Interrupts such as
hardware interrupts belong to these priority classes. When an interrupt
occurs, the operating system automatically calls an assigned organization
block in which the user can program the desired response (for example, in an
FB).
FM
Functional Ground
Ground
Grounding
Hardware Interrupt
Information
Function
Interface,
Multipoint
Interrupt
Glossary
Summary of Contents for simatic c7-621
Page 44: ...2 26 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Installing and Preparing the C7 ...
Page 64: ...3 20 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Configuring an MPI Network ...
Page 74: ...5 4 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Attaching a C7 621 AS i ...
Page 82: ...6 8 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 C7 621 Digital I Os ...
Page 100: ...7 18 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 C7 621 Analog I Os ...
Page 101: ...8 1 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Maintenance 8 ...
Page 110: ...A 8 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 General Technical Specifications ...
Page 123: ...Glossary 1 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Glossary ...
Page 136: ...Index 4 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Index ...