Glossary-3
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
I
Incremental encoders count small increments to acquire paths, positions,
speeds, revolutions, and dimensions, among others.
M
A memory reset deletes the following memory of the CPU.
S
Work memory
S
Read/write area of the load memory
S
System memory except for the MPI parameters and the diagnostic buffer
O
Organization blocks are the interface between the CPU’s operating system
and the user program. The organization blocks specify the sequence in which
the user program is processed.
P
1. A variable of a STEP 7 code block
2. A variable which specifies the reaction of a module (one or more reactions
per module). Each module comes with a realistic basic setting. You can
change this basic setting with the STEP 7 tool
HW Config
.
There are two kinds of parameters -- static parameters and dynamic parame-
ters.
Parameterization sets the reaction of a module.
Programmable Logic Controller
PROcess FIeld BUS is the German process and fieldbus standard which is
specified in the PROFIBUS standard (DIN 19245). This standard specifies
the functional, electrical and physical characteristics for a bit--serial fieldbus
system.
Each bus station must have an address which identifies it unambiguously to
PROFIBUS.
PCs/PGs or the ET 200--Hardheld have PROFIBUS address
²
0.
²
The DP master and the DP slaves have a PROFIBUS address from 1 to 125.
Incremental
encoder
Memory reset
Organization block
(OB)
Parameter
Parameterization
PLC
PROFIBUS
PROFIBUS
address
Glossary
Summary of Contents for SIMATIC CM35
Page 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Page 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Page 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Page 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Page 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Page 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Page 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Page 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Page 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Page 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Page 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Page 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Page 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Page 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Page 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...