3-12
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
3.2.2
Connection Allocation of the 15--Pin Sub D Socket
Table 3-5
Allocation of the 15--pin sub D socket
Pin
Signal
Input/
O t t
Function for Mode
Output
Pulse Counter,
Period Duration
Measurement,
Timer
Positioning
1
VCC1
IN
Load voltage 24 V
2
VCC1
IN
Load voltage 24 V
3
O1
OUT
Digital output 1
Axis 1, forwards
4
O2
OUT
Digital output 2
Axis 1, backwards
5
O3
OUT
Digital output 3
Axis 2, forwards
6
O4
OUT
Digital output 4
Axis 2, backwards
7
GND 2
IN
Ground load voltage for digital outputs
8
GND 2
IN
Ground load voltage for digital outputs
9
VCC1
IN
Load voltage 24 V
10
VCC1
IN
Load voltage 24 V
11
O5
OUT
Digital output 5
Axis 3, forwards
12
O6
OUT
Digital output 6
Axis 3, backwards
13
O7
OUT
Digital output 7
Axis 4, forwards
14
O8
OUT
Digital output 8
Axis 4, backwards
15
GND 2
IN
Ground load voltage for digital outputs
The connections for 24 V load voltage and for ground load voltage are con-
nected internally.
15
8
14
1
Commissioning
Summary of Contents for SIMATIC CM35
Page 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Page 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Page 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Page 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Page 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Page 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Page 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Page 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Page 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Page 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Page 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Page 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Page 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Page 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Page 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...