3-19
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
Note
The latest GSD files (only for COM PROFIBUS version
³
3.3) can be down-
loaded from the Internet (SIMATIC Customer Support).
Internet address: http://www.ad.siemens.de/support/html_00/index.shtml
Copy the new GSD files to the
²
GSD
²
directory, and execute the menu com-
mand
²
File > Open GSD File.
²
Using the GSD files included with the configuration package has a drawback
-- you will not be using the latest GSD file (e.g., you may not be able to find
other new modules).
The type files are only required for older COM PROFIBUS
versions
£
3.2. In the future, they will be completely replaced by the
GSD files.
The module is configured as distributed I/O on the SIMATIC S5 with
COM PROFIBUS.
To add a CM35 to an existing DP master system, proceed as shown below.
1. Start COM PROFIBUS, and open the desired master system.
2. Open a DP slave (ET 200M with IM 153-1), or set up a new one.
3. Place the module in the ET 200M. In the configuration table, select the
desired slot, and select the button
Order No. ...
In the dialog box
²
Select...,
²
select the order number of the CM35
(6AT1 735-0AA0
1-
0AA0), and select the
Accept
button.
4. Leave the configuration table open to set the addresses and operating
mode which come next.
You can specify a start address for the input and for the output area. This ad-
dress depends on the operating mode you want to use.
S
Direct process inputs and outputs: Addresses in the P or Q area
Accesses only permitted via word load and transfer operations
S
Accesses via FB 192: No address specifications required
For a detailed description of FB 192 and its manual, see the manual of
COM PROFIBUS.
Address overlapping with other modules or conflicts with reserved areas are
indicated by COM PROFIBUS.
Configuration
Module
address
Commissioning
Summary of Contents for SIMATIC CM35
Page 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Page 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Page 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Page 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Page 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Page 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Page 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Page 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Page 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Page 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Page 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Page 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Page 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Page 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Page 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...