Brief description of ASM hardware
A.4 ASM 454
FC 45
A-18
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Input parameters for ASM 454
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-11 Input parameters for ASM 454
Address
Name
Permissible values
Comment
+0.0
ASM_address
256, 264, 272, 280, ...
Each ASM 454 occupies 8 byte of I/O
in the I/O area of the control unit
+2.0
ASM_channel
1, 2, 3, 4
4 parallel channels
+8.0
MDS_control
B#16#0, 1, 2
0 = no presence check
1 = presence check
2 = MDS control via NEXT activated
+9.0
ECC_mode
TRUE, FALSE
+9.1
RESET_long
FALSE
(no MOBY U)
+10.0
MOBY_mode
B#16#1, 4, 8, 9
MOBY I dialog with 16KB VMDS on
request. (Dialog only possible with
write/read device of type
write/read device 4x.)
+11.0
scanning_time
B#16#00 ... FF
A value other than 00 is only
recommended when MOBY_mode was
parameterized appropriately (see
Section "INPUT parameters").
+12.0
option_1
B#16#00, 02, 04
See Section "INPUT parameters"
+13.0
distance_limiting
B#16#0
+14.0
multitag
B#16#1
+15.0
field_ON_control
B#16#0
+16.0
field_ON_time
B#16#0
Not relevant (no MOBY U)
Table of commands for ASM 454
The assignment is made in UDT 20 using the "Command" variable (see Section "Command
parameter settings").
Table A-12 Commands for ASM 454
Command code
normal
Chained
1
Description
available in
the MOBY system
01
41
Write to MDS
all
02
42
Read MDS; read fixed code
all
03
43
Initialize MDS
all
06
–
NEXT command. Only permitted when
"MDS_control = 2" is used.
all
1) Chained commands are not supported by all write/read devices. Bitte beachten Sie entsprechende
Please adhere to the information
in the MOBY manuals for configuration, mounting and service.