Parameterizing
3.2 MOBY commands
FC 45
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
3-15
END
Table 3-12 Terminate communication with MDS
Command
[hex]
sub_command
[hex]
length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Note
08
00 = Processing with
MDS has terminated
01 = Processing
pause with MDS
1
–
–
–
ANZ_MDS_present is
reset.
ANZ_MDS_present
remains set.
1) MOBY U:
This command is recommended when scanning_time parameter is greater than 0 (standby time). Use
of this command optimizes the life of the MDS battery. An additional MDS command must now wait
for sleep_time of the MDS to expire again.
Antenna on/off
Table 3-13 Antenna of write/read device ON/OFF
Command
[hex]
sub_command
[hex]
length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Note
0A
01 = antenna
on
02 = stand-by;
antenna off
09 = match antenna
to environment (FFT)
–
–
–
The "antenna on/off"
command connot be
started by command
repetition (see Section
"Command repetition").
Write/read device 80
only (MOBY F)
Only for MOBY F/U/D:
This command is not needed for normal operation because, when a write/read device is
turned on, its antenna is always on.
The antennas must be turned off when two sensitive write/read devices are positioned very
close to each other. The application software must ensure that only one antenna is on at a
time.