100
14.3
Detection Zone Additions
Table 14.3-1:
Detection Zone Additions
14.4
Warning zone
Table 14.4-1:
Technical data – warning zone
14.5
Contour Measurement
Table 14.5-1:
Technical data – contour measurement
Addition with deactivated
dust suppression
83 mm
Addition for activated dust
suppression
83 mm (for a detection zone size < 3.5 m)
100 mm (for a detection zone size
≥
3.5 m)
Addition if retro-reflectors or very
shiny surfaces such as certain
metals or ceramics are present
in the scanning plane
0 mm (more than 1.2 m behind the detection zone
line)
110 mm (in the detection zone or up to 1.2 m
behind detection zone line)
Detection range
0 -15 m
Reflectance factor
min. 20 %
Object size
150 x 150 mm
Response time
Double evaluation: 80 ms (corresponds to 2
scans), up to 16 scans can be selected (640 ms)
Number of warning zones
4/8 (selectable via switch inputs)
Output
PNP transistor output, max. 100 mA
Measurement range
0 - 50 m
Reflectance factor
min. 20 %
Output
Serial interface RS 232 (10 m),
RS 422 (50 m)
Radial resolution
5 mm
Lateral resolution
0.36°