31
a = SIMATIC FS600 Laser
b
= Machine (view from above)
Scanner
c
= Detection zones
d
= Shield plate, flush with the housing
Fig. 5.2-1:
Shielding to prevent direct irradiation
5.2.2
Adjusting adjacent laser scanners
In order to prevent faulty deactivation and scanners interfering with each other as much
as possible, when using several laser scanners you must install these as shown in the
following examples. Installation on the basis of the 3RG7838-1AA installation system
makes precise adjustment significantly easier.
Installation with height offset or a crossed alignment also prevents interference from
beam reflections onto surrounding objects. When safeguarding danger zones, please
also ensure that it is not possible to crawl under the protective field, so that gaps do not
occur with access guarding..