33
In addition, the contours can be infinitely varied by:
•
changing
•
limiting and
•
deleting
partial segments as desired
5.3.2
Range of the Detection Zone, Resolution
The maximum range of the detection zone
S
MAX
4 m (including the additions) for an
object with a diameter of 70 mm and a reflectance factor of 1.8 % (e.g. black corduroy).
The reference point of the measurement is the axis of the rotating mirror on the scanner
64 mm behind the front edge of the scanner.
5.3.3
Range of the Warning Zone, Resolution
A maximum range of 10 meters is available for an object with a diameter of 100 mm. The
maximum available range for an object with a diameter of 150 mm is
15 m. Both of these figures assume a reflectance factor of 20 %.
a = Detection zone
b = Warning zone
c
= Measurement field
Fig. 5.3-1:
Detecting objects in the detection zone and in the warning zone. The
reference point of the distance measurement is the axis of the rotating
mirror.
Resolution in mm
Distance in m
1
2
4
6
8
10
20
40
60
80
100
150
200
500
1000
0
0,2
0,5
1
2
4
6
10
15
20
50
100
b
a
c
Summary of Contents for SIMATIC FS600
Page 2: ...600672 ...
Page 109: ...109 ...