81
10.4
Status information of the SIMATIC FS600 Laser Scanner
1 = LED is lit up
0 = LED is dark
– = undefined
Table 10.4-1:
Status information of the SIMATIC FS600 Laser Scanner
Upon delivery, the SIMATIC FS600 Laser Scanner is programmed with the largest
possible detection zone and with activated startup interlock and manual restart. For this
reason, LED 5 is constantly lit up when the scanner is switched on. When starting up
your SIMATIC FS600 Laser Scanner, please modify the parameters to meet the specific
needs of your application.
Scanner display
LED numbers
1 2 3 4 5
Indicator
Status
– – 1 0 –
LED 3
The OSSD outputs are switched off
(e.g. during booting).
1 0 0 1 0
LED 1
LED 4
The sensor function is active (measurement
operation without an interruption of the
activated zone pair). The OSSDs are
switched “active high”.
1 1 0 1 0
LED 1
LED 2
LED 4
The sensor function is active (measurement
operation without a violation of the activated
detection zone). Violation of the activated
warning zone. The OSSDs are switched
“active high”.
0 1 1 0 –
LED 2
LED 3
Violation of the warning zone. Violation of the
detection zone. The OSSDs are switched off.
1 0 0 1 (1)
LED 1
LED 4
LED 5
The sensor function is active (measurement
operation without a violation of the activated
detection zone). The OSSDs are switched
“active high”. Warning message signaled by
slow flashing at approx. 2 Hz (e.g. with optical
window dirty)
0 0 1 0 (((1)))
LED 3
LED 5
The OSSDs are switched off.
Fault message indicated by fast flashing at
about 4 Hz (e.g. with defect or safety-related
fault)
1 0 1 0 1
LED 1
LED 3
LED 5
The sensor function is active (measurement
operation without an interruption of the
activated zone pair).
The OSSDs are switched off.
Restart interlock is active.
0 1 1 0 1
LED 3
LED 5
Interruption of the zone pair.
The OSSDs are switched off.
Restart interlock is active.