Error Codes
Updating Firmware on
1600T Cameras
E
Rev. 1E, Nov 2007
SIMATIC HawkEye™ 1600T Smart Camera Guide
E-9
>> 2
Enter password to reset User Account to defaults: ******
Exit to Application
The Exit to Application selection exits the Main Menu and switches execution to
the beginning of application code stored in Non-Volatile memory. If there is no
valid application program in Non-Volatile memory, the Main Menu is
re-displayed.
Error Codes
When the Smart Camera fails to boot (i.e., self tests fail), the beeper beeps
continuously and the LEDs on the front of the unit flash the error code in binary
form. Table E–1 describes the Mode/Status LED power-on sequence and error
codes.
TABLE E–1.
Mode/Status LED Power-On Sequence & Error Codes
Mode
Fail
Pass
Trig
Test Performed
•
Data Line Test
•
Address Line Test
•
•
Bootloader CRC Check
•
Kernel CRC Check
•
•
RS-232 Internal Loopback
•
•
FPGA Load Test
•
•
•
FPGA PCI Config Test
•
FPGA Video Buffer Test
•
•
FPGA DMA Transfer Test
•
•
FPGA Expose Done Interrupt Test
•
•
•
FPGA Read Done Interrupt Test