Operating the software
5.3 The tabs of the RF640R/RF670R readers
SIMATIC RF-DIAG
34
Operating Manual, 09/2012, C79000-G8976-C292-01
5.3.2
The "Tag Data" tab
The "Tag Data" tab is displayed only in the advanced view.
Using the "Tag Data" tab, you can verify the transponder data and the basic function of a
reading point quickly and simply. You can read out any data from the transponder or write to
the transponder. When writing to the transponder, you can address all memory areas of the
transponder. With a single command, a maximum of 64 bytes can be read or written.
You can also change the EPC-ID of the transponder.
Figure 5-2
The "Tag Data" tab
Selecting transponders
In the drop-down list of the "Tag to access" area, you can choose the data source via which
the reader will establish the connection to the transponder.
The "Tag ID" list contains all the transponders in the antenna field. You can update the list
with the "Read Tag ID" button. From this list, select the transponder for which you want to
use write or read operations.