Transponder
7.2 MDS D100
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
191
7.2.4
Technical data
Table 7- 3
Technical specifications for MDS D100
6GT2600-0AD10
Product type designation
SIMATIC MDS D100
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OPT memory
•
20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
•
Material
•
PC
•
Color
•
White/petrol
Recommended distance to metal
> 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
During operation
•
-
25 to +80 ℃
•
During transportation and storage
•
-
25 to +80 ℃
Degree of protection to EN 60529
•
IP68
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810
1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810
1)
Torsion and bending load
ISO 10373/ISO 7816-1
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......