Transponder
7.8 MDS D160
SIMATIC RF200
218
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-0AB10
Mechanical strength
•
Isostatic pressure
•
300 bar for 5 min
•
Axial pressure
•
1000 N for 10 s
•
Radial pressure
•
1000 N for 10 s
Resistance to chemicals
All chemicals normally used in the washing pro-
cess
MDS lifespan
At least 100 wash cycles
Degree of protection
•
IP68
24 hours, 2 bar, +20 °C
•
IPx9K
Shock-resistant to IEC 68-2-27
40 g
1)
18 ms; 6 axes; 2000 repetitions/h
Vibration-resistant to IEC 68-2-6
10 g
1)
10 to 2000 Hz; 3 axes; 2.5 h
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
16 x 3 mm
Weight
1.2 g
Type of mounting
•
Patched
•
Sewn in
•
Glued
1
The values for shock and vibration are maximum values and must not be applied continuously.
Note
Regeneration time between washing cycles
The regeneration time for the MDS D160 between washing cycles must be at least 24 hours.
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......