Transponder
7.13 MDS D339
SIMATIC RF200
234
System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.13
MDS D339
7.13.1
Characteristics
MDS D339
Characteristics
Area of application
Applications in production automation with high
temperature demands (up to +220 °C)
Typical application areas:
•
Paintshops and their preparatory treatments
•
Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
•
Top coat area with drying furnaces
•
Washing areas at temperatures > 85 °C
•
Other applications with higher temperatures
Memory size
992 bytes of EEPROM user memory
Write/read range
See section Field data (Page 37).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
7.13.2
Ordering data
Table 7- 31 Ordering data for MDS D339
Article number
MDS D339
6GT2600-3AA10
Table 7- 32 Ordering data for MDS D339 accessories
Article number
Spacer
6GT2690-0AA00
Quick change holder
(Ø x H): 22 x 60 mm
6GT2690-0AH00
Quick change holder
(Ø x H): 22 x 47 mm
6GT2690-0AH10
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......