Transponder
7.15 MDS D421
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
249
Installation examples
Figure 7-37 Installation example of MDS D421 in a steep cone
Figure 7-38 Installation example of MDS D421 in a stud bolt
7.15.4
Technical specifications
Table 7- 38 Technical specifications for the MDS D421
6GT2600-4AE00
Product type designation
SIMATIC MDS D421
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OPT memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black