Transponder
7.15 MDS D421
SIMATIC RF200
250
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-4AE00
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
During operation
•
-
25 to +85 ℃
•
During transportation and storage
•
-
40 to +100 ℃
Degree of protection to EN 60529
•
IP67
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant to EN 60721-3-7 class 7M3
100 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3
20 g
1)
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
10 x 4.5 mm
Weight
Approx. 1 g
Type of mounting
Glued
2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The manufacturer's processing instructions must be observed.
7.15.5
Dimension drawing
Dimensions in mm
Figure 7-39 Dimension drawing of MDS D421
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......