RF200 system planning
4.2 Field data of transponders and readers
SIMATIC RF200
46
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Minimum distance from reader to reader
Table 4- 15 Minimum distances to readers or antennas
RF210R to
RF210R
RF220R to
RF220R
RF240R to
RF240R
ANT x to ANT x
with RF250R
RF260R to
RF260R
ANT Dx to
ANT Dx
with RF290R
≥
60 mm
≥ 100 mm
≥ 120 mm
ANT 3: ≥ 100 mm
≥ 150 mm
ANT D5:
≥ 2000 mm
ANT 8: ≥ 50 mm
ANT D10:
≥ 2000 mm
ANT 12: ≥ 60 mm
ANT 18: ≥ 80 mm
ANT 30:
≥ 100 mm
All values are in mm
Note
Effect on inductive fields by not maintaining the minimum distances of the readers
If the values fall below those specified in the "minimum distance readers or antennas", there
is a risk of the function being affected by inductive fields. In this case, the data transfer time
would increase unpredictably or a command would be aborted with an error.
Keeping to the values specified in the "Minimum distance readers or antennas" table is
therefore essential.
If the specified minimum distance cannot be complied with due to the physical configuration,
the SET-ANT command can be used to activate and deactivate the HF field of the reader.
The application software must be used to ensure that only one reader is active (antenna is
switched on) at a time.
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......