RF200 system planning
4.3 Installation guidelines
SIMATIC RF200
50
System Manual, 07/2015, J31069-D0227-U001-A9-7618
4.3.4
Impact of metal on the transmission window
In general, the following points should be considered when mounting RFID components:
●
Direct mounting on metal is allowed only in the case of specially approved transponders.
●
Flush-mounting of the components in metal reduces the field data; a test is recommended
in critical applications.
●
When working inside the transmission window, make sure that no metal rail (or similar
part) intersects the transmission field.
The metal rail would affect the field data.
●
With readers with a large antenna surface (e.g. RF260R) for reasons of communication
reliability, when the transponders are flush mounted in metal, a metal-free space around
the transponders is recommended. This metal-free space should match the size of the
antenna surface.
The impact of metal on the field data (S
g
, S
a
, L) is shown in a table in this section. The
values in the tables describe field data reduction and show the reduced range as a
percentage. The range relates to use in a non-metallic environment. A value of 100% means
no influence on the range.
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......