5.6 SIMATIC RF260R
SIMATIC RF200
122
System Manual, 07/2015, J31069-D0227-U001-A9-7618
5.6.3
Pin assignment RF260R
Pin
Pin
Device end 8-
pin M12
Interface assignment
RS-422
RS-232
1
+24 V
+24 V
2
- Transmit
RXD
3
0 V
0 V
4
+ Transmit
TXD
5
+ Receive
Unassigned
6
- Receive
Unassigned
7
Unassigned
Unassigned
8
Ground (shield)
Ground (shield)
5.6.4
Display elements of the RF260R reader
Color
Meaning
green flashing
Operating voltage present, reader not initialized or antenna switched off
permanently
lit
Operating voltage present, reader initialized and antenna switched on
yellow
1)
Transponder present
flashing red
Error has occurred, the type of flashing corresponds to the error code in the
table in the section "Error codes". The optical error display is only reset if the
corresponding reset parameter ("option_1 = 2") is set (see Product infor-
mation "SIMATIC RF200 command set"
https://support.industry.siemens.com/cs/us/en/view/44864850
1)
Only in the "with presence" mode.
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......