Readers
5.7 SIMATIC RF290R
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
137
6GT2821-0AC12
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 … +55 °C
•
During transportation and storage
•
-25 … +85 °C
Degree of protection to EN 60529
IP65
Shock-resistant to EN 60721-3-7, Class 7 M3
30 g
Vibration-resistant to EN 60721-3-7, Class 7 M3 2 g
Torsion and bending load
Not permitted
Design, dimensions and weights
Dimensions (L x W x H)
140 × 200 × 80 mm
Weight
1.8 kg
Type of mounting
2 x M5 screw
1.5 Nm
Cable length, maximum
•
RS-422: max. 1000 m
•
RS-232: max. 30 m
LED display design
4 LEDs
5.7.7
Approvals
FCC information
Siemens SIMATIC RF290R (MLFB 6GT2821-0AC12) FCC ID NXW-RF290R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......