Transponder
7.8 MDS D160
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
217
7.8.4
Technical specifications
Table 7- 20 Technical specifications for the MDS D160
6GT2600-0AB10
Product type designation
SIMATIC MDS D160
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OPT memory
•
20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40
℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
•
Material
•
Color
•
PPS
•
beige
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
In operation, during write/read access
•
-25 … +85 °C
•
In operation, outside write/read access
•
-40 … +175 °C
•
from +125 ℃: for 1000 hours, 20% reduction
of the limit distance
•
from +140 ℃: No processing possible
•
at +175 ℃: 100 washing cycles tested
•
at +220 ℃: Tested once for up to 30 seconds
•
During transportation and storage
•
-
25 to +100 ℃
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......