Transponder
7.10 MDS D200
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
225
Flush-mounting
a
≥ 20 mm
h
≥ 20 mm
①
Data memory
②
Metal
③
Non-metal
Figure 7-21 Flush-mounting of MDS D200 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
7.10.4
Technical data
Table 7- 25 Technical specifications for MDS D200
6GT2600-1AD00-0AX0
Product type designation
SIMATIC MDS D200
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
256 bytes EEPROM
•
OTP memory
•
20 bytes EEPROM