Transponder
7.18 MDS D424
SIMATIC RF200
260
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Flush-mounting
h
≥ 15 mm
a
≥ 25 mm
Figure 7-47 Flush-mounting of the MDS D424 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is
possible to mount the MDS with metal screws (M3 countersunk head screws). This has no
tangible impact on the range.
7.18.4
Technical specifications
Table 7- 46 Technical specifications for the MDS D424
6GT2600-4AC00
Product type designation
SIMATIC MDS D424
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OPT memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field