Transponder
7.21 MDS D428
SIMATIC RF200
270
System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.21.3
Application example
Figure 7-52 Application example
7.21.4
Technical specifications
Table 7- 53 Technical specifications for the MDS D428
6GT2600-4AK00
Product type designation
SIMATIC MDS D428
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OPT memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at
< 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
MTBF (Mean Time Between Failures)
2 x 10
6
hours