Transponder
7.24 MDS D522
SIMATIC RF200
282
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
●
Drill installation hole
●
The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
●
Apply adhesive according to the manufacturer's processing instructions
●
Press in MDS D522 using your fingers; with antenna to the outside
●
Remove residues of adhesive
●
Allow to cure according to the manufacturer's instructions
●
Flush-mounting of MDS D522 in metal with tools
7.24.4
Technical specifications
Table 7- 60 Technical specifications for MDS D522
6GT2600-5AF00
Product type designation
SIMATIC MDS D522
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
MTBF (Mean Time Between Failures)
2.5 x 10
6
hours
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF; brass nickel plated
•
Color
•
Black/silver
Recommended distance to metal
> 0 mm
Power supply
Inductive, without battery
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......