RF200 system planning
4.2 Field data of transponders and readers
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
37
4.2.1
Field data
The limit distances (S
g
) and operating distances (S
a
) along with the length of the
transmission window for each reader-transponder combination are listed in the tables below.
Table 4- 1
SIMATIC RF210R field data
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
25
1 ... 18
20
MDS D127
1)
3
0 ... 2
2
MDS D160
20
1 ... 10
12
MDS D324
20
1 ... 8
9
MDS D421
5
0 ... 3
4
MDS D422
8
1 ... 9
10
MDS D423
20
2 ... 10
12
MDS D424
24
1 ... 16
18
MDS D425
12
1 ... 6
7
MDS D428
20
1 ... 10
11
MDS D460
8
1 … 8
9
MDS D521
5
0 ... 3
4
MDS D522
8
1 ... 8
9
MDS D522
Special variants
8
1 ... 8
9
MDS D524
20
1 ... 15
17
MDS D528
15
1 ... 10
11
1)
The transponder is only suitable for static mode.
All dimensions in mm.
Table 4- 2
SIMATIC RF220R field data
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
35
1 ... 28
31
MDS D126
45
2 ... 30
35
MDS D160
20
1 ... 20
22
MDS D324
30
2 ... 21
25
MDS D422
18
1 ... 12
14
MDS D423
30
2 ...24
28
MDS D424
30
2 ... 25
29
MDS D425
20
1 ... 11
13
MDS D426
40
2 ... 25
30
MDS D428
25
1 ... 18
21
MDS D460
25
1 ... 18
20
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......