Configuration
7.1 Management Explorer
SIMATIC IPC DiagMonitor V5.1.6
Operating Manual, 05/2021, A5E50981422-AA
43
7.1.10
MiniWeb Server
7.1.10.1
MiniWeb Server
The MiniWeb server provides information on the system via HTTP/HTTPS.
Make sure that the ports used have been enabled in the firewall of your operating system. For
additional information on changes, see Changing the MiniWeb Network Port (Page 43).
Following installation, you can start and stop the MiniWeb server via Management Explorer.
For additional details, see Starting and stopping the MiniWeb server (Page 43).
7.1.10.2
Starting and stopping the MiniWeb server
1.
Start the Management Explorer.
2.
Select "Web server" from the "Options" menu.
7.1.10.3
Changing the MiniWeb Network Port
The default values for the network ports are 5009 for HTTP and 5449 for HTTPS. To change
this setting, proceed as follows:
1.
Start the link "Start > Programs > Siemens Automation > DiagBase > WebServer >
Configuration".
2.
Search for the line <PORTNUMBER VALUE="5009"/>.
3.
Change the value of the respective http port.
4.
Search for the line <SSLPORTNUMBER VALUE="5449"/>.
5.
Change the value of the respective HTTPS port.
6.
Save and close the file.
7.
Restart the MiniWeb service (see Starting and stopping the MiniWeb server (Page 43)).
7.1.10.4
Opening the MiniWeb Site
If the MiniWeb service has been started (see Starting and stopping the MiniWeb server
(Page 43)), you can open the website using a browser. If you want to open the website of the
local computer, enter the following address in the address line of the browser:
http://localhost:5009
or
https://localhost:5449
. If you want to open the website of another
computer:
http://Computer name:Port
or
http://IP address of the computer:Port
. Make
sure that the firewall of your operating system has been configured so that you can access
the respective port.