Technical specifications
8.4 Technical data
SIMATIC IPC277G
84
Operating Instructions, 08/2021, A5E50059956-AA
Electromagnetic compatibility
Radiation Emission (Enclosure port)
in accordance with IEC 61000-6-3
+ A1/ CAN/CSA-CISPR 22:10
•
30 to 230MHz: 30dB(uV/m) quasi-peak(10m distance)
•
230 to 1000MHz: 37dB(uV/m) quasi-peak(10m distance)
•
1 to 3 GHz: 76dB(uV/m) peak; 56dB(uV/m) average (3m
distance)
•
3 to 6 GHz: 74dB(uV/m) peak; 54dB(uV/m) average (3m
distance)
Immunity with regard to
conducted interference on the
supply lines
•
Burst: ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-
4-4;
•
Surge: ± 1kV line to line, ±2 kV line to earth in accordance
with IEC 61000-4-5;
Noise immunity on signal lines
Burst:
•
± 1 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4;
Length of signal port extension cable < 30 m;
•
± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4;
Length of signal port extension cable
≥
30 m;
Surge:
•
±2kV shielding-to-earth in accordance with IEC 61000-4-5;
Length of signal port extension cable
≥
30 m;
Immunity to discharges of static
electricity
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
Immunity to RF interference
Radiation Immunity (according to IEC 61000-6-2)
•
80 MHz to 2GHz
10 V/m, 80 % AM (1 kHz)
•
2 GHz to 6.0 GHz
3 V/m, 80 % AM (1 kHz)
Conducted Immunity (according to IEC 61000-4-6)
•
10 kHz to 80 MHz: 10 V, 80% AM (1kHz)
Conducted Emission (Low voltage
DC mains port), in accordance with
IEC 61000-6-3 + A1
•
0.15 to 0.5 MHz / 79 dB (
μ
V) Q, 66 dB (
μ
V) M
•
0.5 to 30 MHz / 73 dB (
μ
V) Q, 60 dB (
μ
V) M
Conducted
Emission(Telecommunications/Net
work Port),
in accordance with IEC 61000-6-3
+ A1
0.15 to 0.5 MHz:
84 dB(
μ
V) to 74 dB(
μ
V) Q
74 dB(
μ
V) to 64 dB(
μ
V) M
0.5 MHz to 30 MHz:
74 dB(
μ
V) Q / 64 dB(
μ
V) M