Installing and connecting the device
3.2 Mounting the device
SIMATIC IPC527G
Operating Instructions, 03/2019, A5E45491226-AA
21
Vertical mounting position
For these two vertical mounting positions, you can use the following mounting types:
●
Wall mounting
●
Book mounting
●
Tower mounting
Take into account the permitted temperature range for operation that depends on the
mounting position in accordance with the "Environmental conditions (Page 65)" section.
3.2
Mounting the device
3.2.1
Mounting instructions
Note
If the equipment is used in a manner not specified by the manufacture, the protection
provided by the equipment might be impaired.
Note the following:
●
The device is approved for indoor operation only.
●
When the device is used in the area of Industrial Control Equipment in accordance with
UL61010-2-201, the device is classified as "Open equipment". Open equipment must be
installed within an enclosure which protects you from hazards, including mechanical
hazards, electrical shock and spread of fire.
●
Install the device only in one of the described permitted mounting positions.
●
For installation of control cabinet, observe the country-specific regulations.
●
All the external circuit of the device must be SELV circuit.