Start-up
SIMATIC MV230
20
Operating Instructions, 01/2007 Edition, A5E00749101-01
Line Length
Line Length can be used to limit the evaluation range of the laser line. This is
particularly recommendable with small objects which are only covered by a
small section of the laser line.
The basic setting of the evaluation range is 100 % and can be minimized to
30 % in steps of 10 %. The evaluation range always commences from the right
(with viewing direction onto display side of sensor) up to the selected percent-
age value:
Note
The sensitivity of the sensor is increased when the evaluation range
is limited.
Note
If the evaluation range is changed for models which have already
been trained, these should be trained again and checked in test
mode.
&RQILUPE\SUHVVLQJNH\2.!
6HWUHTXLUHGSHUFHQWDJHQXPEHU
&RQILUPE\SUHVVLQJNH\2.!
Line length
PLQ