Process interfacing via an automation system (PLC, PC)
10.1 Integration via Onboard PROFINET IO
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
239
10.1.3
Concept of device replacement
Note
Settings/programs of the reader being replaced as an XML file
For simple device replacement, you save the settings and programs of the reader you are
replacing as an XML file.
Note
The topology of the system must be correctly configured
To be able to replace the device without an exchangeable medium, the topology of the
system must be correctly configured. Use the topology editor for this.
Select "Support device replacement without exchangeable medium"
●
For a simple device replacement, select the PROFINET functionality "Support device
replacement without exchangeable medium":
With this setting, the new reader receives its device name directly from the IO controller. The
IO controller uses the configured topology and the neighborhood relations detected by the IO
devices.