Process interfacing via an automation system (PLC, PC)
10.2 Integration via communication module (ASM)
SIMATIC MV420 / SIMATIC MV440
240
Operating Instructions, 04/2013, A5E02371045-06
Replacing the device: Procedure
1.
Replace the reader with a new reader with the factory settings.
2.
Wait until the new reader is automatically assigned the IP address of the device that was
replaced.
3.
Start of the adjustment support using this IP address in the browser.
4.
Start to restore the settings from the saved XML parameter file using the adjustment
support. Make sure that the options "TCP/IP settings" and "PROFINET IO settings" are
selected.
5.
Wait until the parameters have been restored.
6.
Following the automatic restart, the reader is ready for operation.
10.2
Integration via communication module (ASM)
The reader supports a subset of MOBY commands.
The reader can be integrated via the RS 422 interface as a write/read device (compatible
with RF300) using a communication module (ASM).
The hardware integration of the communication modules is described in the operating
instructions of the respective device.
The following parameters must be set for the configuration of the communication module:
Table 10- 1 Configuration parameters
Parameter
Value
Note
FB45 / FC45
USER_Mode
RFID standard profile
Use Ident profile (PIB_1KB,
PIB_16KB, PIB_32KB).
MOBY_Mode
MOBY U / D/ RF300
normal addressing
Baud rate SLG RF300 /
MOBY U / D
•
19.2 kbaud
•
57.6 kbaud
•
115.2 kbaud
The selection must be identical
to the configuration of the
reader.
Diagnostics with diagnostics
messages
none
Standard diagnostics.
The diagnostics of the reader
uses a separate mechanism.