Process interfacing via an automation system (PLC, PC)
10.3 Control with FB 45 and Ident profile
SIMATIC MV420 / SIMATIC MV440
244
Operating Instructions, 04/2013, A5E02371045-06
WRITE-CONFIG
Table 10- 2 Command parameter
Variable
Value
Config
3
Length
16
Table 10- 3 Command data appendix
Variable
Value
Description
Byte 1
4
Length of the subsequent sub-parameter
in hex, here 4.
Bytes 2 to
5
0
Byte 6
10
Length of the subsequent sub-parameter
in hex, here 16.
Byte 7
0
Byte 8
0
Byte 9
0
Byte 10
0x25
Setting of the MOBY operating mode.
Byte 11
2
Option
Byte 12
0
Byte 13
0
Byte 14
1
Number of MDS
Byte 15
0
Byte 16
0: INIT without program selection,
1 ... 15: Number of the program to be
started (INIT with program selection)
Table 10- 4 Command parameter
Variable
Value
Config
1
Length
0 (no data appendix)
The command parameters are possible (onboard PROFINET IO) only if no communication
module is used. Corresponds to the INIT without program selection.