Process interfacing via an automation system (PLC, PC)
10.6 Control via TCP/IP and RS-232
SIMATIC MV420 / SIMATIC MV440
316
Operating Instructions, 04/2013, A5E02371045-06
Application: Evaluate two 1D/2D codes per image (multicode)
●
Current program number is "5".
●
New 1D/2D code match string for code index 1 and 2 for trigger number 42
●
No OCR
Total length
30
Trigger ID
42
Flags
0
Code No Cnt
1
Code No
5
Code Idx Cnt
2
Code Idx
1
String length
8
String
"SN012345"
Code Idx
2
String length
8
String
"SN612345"
ROI ID Cnt
0
XOR checksum
0
10.6.13
Set digital out
Note
Availability of "Digital Out"
The "Digital out" function is not available for SIMATIC MV420 SR-B.
Writing command data
●
With this command, the four logical signals "EXT_1", "EXT_2", "EXT_3" and "EXT_4" can
be set and linked to other logical signals. These signals can only be set via an automation
system.
●
These signals can also be applied to the available digital output pins using adjustment
support.
●
Receipt of this command is logged in the diagnostics data records.