Alarm, fault and system messages
11.2 Reporting diagnostics information
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
343
Error code
(%c)
Message (%s)
Description
0014
Only m of the expected number of 1D/2D codes
found in step n
Only m instead of the expected number of codes was
found in step # n with multicode decoding.
0015
Maximum number of codes per image (m)
exceeded in step n
More than the maximum number of codes were found
with multicode decoding (per image: 50 (MV440 UR:
150)).
0016
Exceeded maximum decodable data length in
code m of step n
A maximum of 3001 bytes can be decoded per step.
This amount was exceeded for code #m in step #n.
1006
No Text found in step n
OCR: No text found in step #n.
1007
Text too short in step n
OCR: The text found in step #n is shorter than the
configured minimum.
1008
Text too long in step n
OCR: The text found in step #n is longer than the
configured maximum.
1009
Quality too low in step n
OCR: The text found in step #n is below the
configured quality threshold.
1010
Match failure in step n
OCR: The match performed in step #n was not
successful.
1011
Missing preknowledge for step n
OCR: There is no string specification available for
step #n.
4700
Verification Process Error in step n
"Siemens DPM" verification reports: Not enough
space around the data matrix code in step #n.
4701
Verification Unsupported in step n
The selected verification method is not supported for
the code type found in step #n.
4709
Mean light out of range in step n
"AIM DPM" verification reports: Average brightness
value is out of range (70% ... 86%) in step #n.
4710
ISO Verification ECC200 required in step n
Verification according to "ISO15415" and "AIM DPM"
does not support data matrix codes that are not
ECC200. The error occurred in step #n.
4711
ISO Verification aperture too small in step n
The cell size of a data matrix code in step #n is too
large for the set aperture.
4712
ISO Verification aperture too large in step n
The cell size of a data matrix code in step #n is too
small for the set aperture.
4713
ISO Verification insufficient space in step n
"ISO15415" or "AIM DPM" verification reports: Not
enough space around the data matrix code in step #n
4714
ISO Verification failed RDA STEP F1 in step n
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f), 1 to 6 for page 1. The
error occurred in step #n.
4715
ISO Verification failed RDA STEP F2 in step n
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f), 1 to 6 for page 2. The
error occurred in step #n.
4716
ISO Verification failed RDA STEP F3 in step n
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f) 7. The error occurred in
step #n.