Device Management
3.2 Configuring the Device
Ethernet Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RST916C console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RST916C is
For more information about available ports, refer to
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured.
All configuration management is done via the RUGGEDCOM RST916C interface.
For more information about configuring the device, refer to the
RUGGEDCOM ROS
Configuration Manual
associated with the installed software release.
3.3
Inserting/Removing the CLP
The following describes how to insert and remove the Configuration and Licensing
Plug (CLP).
NOTICE
Security hazard – risk of unauthorized access and/or exploitation
Make sure to remove the CLP before decommissioning the device or sending the
device to a third-party.
NOTICE
Mechanical/electrical hazard – risk of damage to the CLP
• Do not expose the CLP to extreme temperatures or humidity
• Do not expose the CLP to large magnetic or static electric fields
• Do not bend or drop the CLP
NOTICE
Contamination hazard – risk of equipment damage
A blank insert is included with the device. Use the blank insert when the CLP is
removed to prevent the ingress of water, dirts and other debris.
20
RUGGEDCOM RST916C
Installation Manual, 04/2021, C79000-G8976-1490-03